Drive system related service call
[C010] Main motor is abnormal
Classification | Error content |
Drive system related service call | Main motor is abnormal |
Call for service C010- Toshiba 2528A Photocopy machine
Proce dure | Check item | Result | Measure | Next Step |
1 | Is the main motor working? (Perform the output check in the test mode: 03-101/151) | Yes |
| 2 |
No | 1. Check if the connector (CN650, CN651) of the main motor is disconnected. 2. Check if the connector CN303 on the LGC board is disconnected. 3. Check if the connector pins are disconnected and the harnesses are open circuited. 4. Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 5. Replace the main motor. 6. Replace the LGC board. |
| ||
2 | Are there any damage or scratches on the main motor board? | Yes |
| 3 |
No | 1. Check if the connector pins are disconnected and the harnesses are open circuited. 2. Check if the conductor patterns on the main motor board and LGC board are short circuited or open circuited. 3. Replace the main motor. 4. Replace the LGC board. |
| ||
3 | LGC board |
| 1. Check if the PLL lock signal CN303-7 output from the LGC board is always level “L”? 2. Check if the voltage supplied to the CPU input terminal IC22-98 is always “L”? 3. Replace the LGC board. |
|
Parts to be replaced | Remark |
Main motor |
|
LGC board |
|
আপনি যদি সমস্যাটির সমাধান না করতে পারেন তাহলে আমাদের দক্ষ ইঞ্জিনিয়ারের মাধ্যমে সমাধান করিয়ে নিতে পারেন।
Contact With us..
Address : 55/B, purana polton Dhaka
Mob : 01611-482988
Hot Line: 01843-209242
E-mail : ikinternational061@gmail.com
E-mail: support@toshibabd.com
Facebook Group: Join Now
Facebook page : Follow Now
YouTube: Watch our service videos
web : visit now
web : Visit now
Misfeed copier E020 Toshiba photocopy machine